H07V-F Rubber Cable
H07V-F Rubber Cable
1.Rated voltage:450/750V
2.CE certification
3.VDE standard
VDE 450/750V flexible wire h07rn-f rubber cable
H07V-F Rubber Cable ------------ Applications:
The h07rn-f rubber cable are mostly used as power cable for equipment in industry work such as boilers, heating plates, hand lamps, transportable motor etc. They can be installed at medium mechanical stress in dry, damp and wet areas as well as in open air and in agriculture plants. These cables are also suitable for fixed installation on plaster, in temporary buildings and residential barracks. They are suitable for direct laying on components and mechanical parts of machines like lifts and cranes.
The cables can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage up to and including AC 1000V or DC 750V against ground.
H07V-F Rubber Cable ------------ Characteristics
1.- They are designed to provide high flexibility and have the capacity to withstand weather, oil, mechanical and thermal stresses.
2.- Special wind torsion test: the e H07RN-F cable passes the special 2.000 cycle Torsion Test required for wind generators (for single core cables].
3.- Improved working temperature: The H07RN-F can operate at work temperatures up to
90°C, improving the HD 22 standard rated temperature, due to insulation with high thermal grade.
4.- Rated voltage up to 1000 V: possible thanks to the high dielectric properties of the insulation material (according to HD 5163.)
5.- Weather resistance: The properties of the thermosetting vulcanized rubber outer sheath on the H07RN-F cables allows a permanent use outdoors.
6.- Immersion resistance: Exceeds the established tests for type H07RN8-F, suitable for functioning permanently submerged CAD83.
7.- Resistance to chemical products: Vulcanized rubber outer sheath is the most effective protection against chemical products such as hydrocarbons and mineral oils.
8.- With-stand short contacts at high temperature: Due to the vulcanized materials used, this cable can with-stand short-term contact with hot surfaces (5 seconds at 250°C without damage.
Fixed installation: open air installation, one cable with effective air renewal and with ambient temperature of 30°C, fixed by cleats an hangers or on perforated tray (reference method F for single core and E for multi-core cables).
For cables with 2 or 3 conductors it is supposed a single-phase circuit.
For cables with 1, 4 or 5 conductors it is supposed a three-phase circuit.
For cables with 6 or more conductors it is supposed a single-phase circuit where not all conductors are fully loaded simultaneously.
H07V-F Rubber Cable ------------ specifications:
|
Cross-section mm2 |
Diameter mm |
Weight kg/km |
Resistance at 20°C Ω/KM |
Mobile service30°C A |
Fixed installation 30°C A |
Voltage drop V/A km |
|
4-CORE |
|
|||||
|
4x1 |
9,6 |
130 |
19.5 |
10 |
17 |
39,2 |
|
4x1.5 |
10,6 |
164 |
13.3 |
16 |
23 |
26,7 |
|
4x2.5 |
12,4 |
237 |
7.98 |
20 |
32 |
16,0 |
|
4x4 |
14,5 |
337 |
4.95 |
30 |
42 |
9,95 |
|
4x6 |
16,3 |
452 |
3.3 |
37 |
54 |
6,63 |
|
4x10 |
21,3 |
781 |
1.91 |
52 |
75 |
3,84 |
|
4x16 |
24,2 |
1,077 |
1.21 |
69 |
100 |
2,43 |
|
4x25 |
30,5 |
1,667 |
0.78 |
92 |
127 |
1,57 |
|
4x35 |
33,3 |
2,156 |
0.554 |
114 |
158 |
1,11 |
|
4x50 |
38,6 |
2,971 |
0.386 |
143 |
192 |
0,776 |
|
4x70 |
43,1 |
3,934 |
0.272 |
178 |
246 |
0,546 |
|
4x95 |
54,1 |
6,360 |
0.206 |
246 |
346 |
0,323 |
|
4x120 |
49,5 |
5,199 |
0.161 |
210 |
298 |
0,414 |