Rubber Welding Cable Application
Welding Cables are flame retardant, oil resistant, resilient, resists compression cuts and abrasion,
durable, and survives rough handling.
Designed for use as arc welding leads from the secondary side of the power source, typical of welders and welding generators. Not for primary voltage.
Rubber Welding Cable Construction
Welding Cables are manufactured using annealed rope-stranded bare copper conductor as per ICEAS-75-381.
A paper tape separates the conductor insulation. A medium-duty EPR jacket is extruded onto the cable.
EP or Hypalon jackets are available. 600 volt spark tested.
Rubber Welding Cable Standard
ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1.
Rubber Welding Cable Specification
Medium Duty jacket made accordance with ICEA S-75-381 - Portable and Power Feeder Cables for Use in Mines and Similar Locations or IEC 245-1 600 Volt Spark tested
Rubber Welding Cable Technical data
|
Conductor Size(AWG) |
Conductor Stranding (#/AWG) |
Nominal Resistance of Conductor at 25°C (Ohms / 1000 ft) |
Nominal Thickness of Insulation (Inches) |
Nominal overall Diameter (Inches) |
Approximate Net Weight (LBS/1000 Ft) |
|
2 |
652 / 30 |
0.167 |
0.071 |
0.48 |
260 |
|
1/0 |
1043 / 30 |
0.105 |
0.079 |
0.57 |
400 |
|
2/0 |
1297 / 30 |
0.0842 |
0.079 |
0.64 |
500 |
|
4/0 |
2065 / 30 |
0.053 |
0.079 |
0.77 |
760 |
Keywords: Rubber Cable , Rubber Flexible Cable