Rubber Insulated 50mm2 Welding Cable

Rubber Insulated 50mm2 Welding Cable

Rubber Insulated 50mm2 Welding Cable

Description


Rubber Insulated 50mm2 Welding Cable


rubber welding cable
rubber insulated cable

Rubber Insulated 50mm2 Welding Cable Application
These rubber cables are designed to provide high flexibility and have the capacity to withstand weather, oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.

rubber insulated cable

Standards
BS7919, CENELEC HD22.4 S4

Rubber Insulated 50mm2 Welding Cable Technical data

Conductor
Class 5 flexible plain copper
To BS EN 60228: 2005 (previously BS6360)

Insulation
EPR(Ethylene propylene rubber) type E14 to BS 7655

Sheath
PCP (Polychloroprene) Type EM2 to BS7655

Sheath color
Black

Voltage rating
450/750V

Temperature rating
Conductor operating temperature
-300C to +600C(850C max. )

Min. Bending radius
Up to 25mm2: 6 X overall diameter
Above 25mm2: 8 X overall diameter

Core identification:
2 cores: Blue, Brown
3 cores: Green/Yellow, Blue, Brown
4 cores: Green/yellow, Brown, Black, Grey
5 cores: Green/yellow, Blue, Brown, Black, Grey
6 cores and above: Black with white numbers, Green/Yellow

Rubber Insulated 50mm2 Welding Cable Feature
1. rubber welding cable
2.Rubber Insulated electric wire
3.CCC IEC Certification
Parameter
1.Voltage Uo/U 450/750V 
2.Max. Permissible Continuous Operation Temperature of The Conductor: 70°C
3.The Ambient Temperature Under Installation Should Not Below 0°C
4.Impedance (ohms): 100±2ohm
Specification
Type: YH YC YZ 
Voltage: 300/500v 450/750v
Specification: Electric Wire 10mm2-185mm2 etc
Length: 100M 200M 300M 500M
Application
 rubber welding cable are suitable for household electrical appliances, small electric power tools,  
AC rated voltage up to and including 450/750V,  and below the small household electrical appliances, electric tools,
instruments and apparatuses and lighting devices, which is used for connecting power line.
Detailed Product Description
1th. Service Conditions
This product is suitable for the welding machine whose voltage to the ground is not more than 200V and pulsating current value is 400V.
2th.  Model, Names Main applications and Work In the Temperature
Model Name Main applications Working temperature
of core ≤0C
YH Natural Rubber Sheath for Welding Cable Always used indoor 65
YHF Neoprene Rubber Sheath Welding Cable Always used outdoor 65
Synthetic elastomer Sheath Welding Cable


rubber welding cable
rubber insulated cable


Conductor Nominal Section
(mm2)
Conductive Core Thickness of Section
Sheath (mm)
Average Outer Diameter (mm2) 20oC Conductor Resistance≤(Ω/km) Reference
Weight(kg/km)
Number/Diameter of Core(mm) Min Max YH YHF
10 322/0.20 1.8 7.5 9.7 1.91 146 153.51
16 513/0.20 2.0 9.2 11.5 1.16 218.9 230.44
25 798/0.20 2.0 10.5 13.0 0.758 316.6 331.15
35 1121/0.20 2.0 11.5 14.5 0.536 426 439.87
50 1596/0.20 2.2 13.5 17.0 0.379 592.47 610.55
70 2214/0.20 2.4 15.0 19.5 0.268 790 817.52
95 2997/0.20 2.6 17.0 22.0 0.198 1066.17 1102.97
120 1702/0.30 2.8 19.0 24.0 0.161 1348.25 1392.55
150 2135/0.30 3.0 21.0 27.0 0.129 1678.5 1698.72
185 1443/0.40 3.2 22.0 29.0 0.106 1983.8 2020.74